Accessories
E 1100
76
wc_tx001844gb.fm
5.7
Connecting two HX 50 Heat Exchangers
Requirements
Machine stopped
Two HX 50 Heat Exchangers
One 2-1 adapter
One 1-2 adapter
Limitations
Maximum run (horizontal distance from HX to machine): 228 m (750 ft)
Maximum rise (vertical distance of HX above machine): 76 m (250 ft)
Maximum run at maximum rise: 215 m (707 ft)
Note:
The farther the HX is positioned from the parent machine, the more heat will
be lost through the hose. This may affect HX performance.
Procedure
Perform the procedure below to connect the Heat Exchangers to the machine.
1. Stop the parent machine temporarily.
2. Position the Heat Exchangers within the space to be heated.
This procedure continues on the next page.
0 – 76 m (250 ft)
0 – 228 m (750 ft)
0 – 215 m (707 ft)
wc_gr008096
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......