E 1100
Burner Setup
wc_tx001811gb.fm
81
6.1
Setting/Checking the Electrodes
Requirements
Power supplies disconnected
Measuring device
Procedure
Follow the procedure below to check the electrodes.
1. Disconnect the power supplies feeding the machine.
2. Loosen the copper fuel line
(a)
between the fuel pump and the burner housing.
3. Remove the spline nut
(b)
that is seated against the escutcheon plate.
4. Loosen tabs
(c)
and open the igniter cover.
.
5. Maneuver the nozzle assembly
(d)
up and out of the burner.
6. Disconnect the wiring
(e)
from the fuel preheater.
This procedure continues on the next page.