Burner Setup
E 1100
82
wc_tx001811gb.fm
Continued from the previous page.
7. Remove the turbulator assembly
(f)
from the nozzle assembly.
8. Use the measurements below to properly set the electrodes.
9. After the electrodes are set, reinstall the turbulator assembly.
10.Reconnect the preheater wiring.
11.Reinstall the nozzle assembly into the burner.
Result
The electrodes have now been checked/adjusted.
Ref.
Description
Gap distance
h
Electrode tip to electrode tip
5/32 in. (4 mm)
i
Nozzle center to electrode tip
5/16 in. (7.5 mm)
j
Nozzle end to electrode tip end
1/16 in. (1.5 mm)
wc_gr008520
f
Summary of Contents for 5000620172