BA 50Z3/6003 en – Edition 4.3 * 5003b530.fm
5-51
Maintenance
5.18 Central lubrication system (option)
Grease-based central lubrication system with 12 lubrication points.
Not in connection with triple articulation boom (option).
Function
The green LED illuminates for about 1.5 sec once ignition is switched on to indicate readiness.
Pressing the push button on the pump’s motor housing switches on the pump and starts
the lubrication cycle. The pump drive motor is switched off and cycle time begins once
lubrication time is over.
All further lubrications start automatically according to the cycle time set.
Lubrication time is stopped and saved if ignition or lubrication is switched off during cycle
time. The data is read from the memory upon switching ignition on again, and lubrication is
resumed where it was interrupted.
Pressing the push button on the motor housing or on the instrument panel starts intermedi-
ate lubrication if ignition is switched on.
Status LEDs
4
1
5
3
2
Pos.
Designation
1
Push button on motor housing
2
Red LED
3
Green LED
4
Lubrication time potentiometer
5
Cycle time potentiometer
Indication
Meaning
Green LED 1.5 sec
Ignition on (operational readiness)
Steady green light
Illuminates during lubrication
Steady red light
Grease level error
Remains lit until grease tank is refilled
Blinking red light
Overpressure error
Summary of Contents for 50Z3
Page 35: ...BA 50Z3 6003 en Edition 4 3 5003b110 fm 1 23 Introduction Overview of safety labels ...
Page 56: ...2 16 BA 50Z3 6003 en Edition 4 3 5003b210 fm Safety instructions ...
Page 178: ...3 122 BA 50Z3 6003 en Edition 4 3 5003b340 fm Operation ...
Page 190: ...4 12 BA 50Z3 6003 en Edition 4 3 5003b410 fm Troubleshooting ...
Page 254: ...5 64 BA 50Z3 6003 en Edition 4 3 5003b560 fm ...
Page 265: ...BA 50Z3 6003 en Edition 4 3 5003b610 fm 6 11 Specifications 6 16 Dimensions model 50Z3 ...
Page 267: ...BA 50Z3 6003 en Edition 4 3 5003b610 fm 6 13 Specifications 6 17 Dimensions model 50Z3 VDS ...