12 Troubleshooting
,
12.1
Fault table - rechargeable battery
12.2
Fault table
DANGER
Danger to life from unauthorized troubleshooting.
If faults occur with this machine that are not described in this manual, contact the
manufacturer. Do not eliminate the faults independently.
Pictogram
LED over
Pictogram
Possible causes
Remedial measure
Fault LED
comes on.
Voltage too high.
Isolate the rechargeable battery
from the machine or the charging
unit.
Fault LED
stays on.
Contacting error.
Hardware error.
Clean and if necessary dry the
contacts.
Resume operations with the
machine and clear the fault with the
button.
*
Temperature LED
comes on.
Temperature error
(over / under temperature).
Operate the machine only in the
permitted temperature range.
Allow the equipment to cool down if
necessary.
Resume operations with the
machine and clear the fault with the
button.
Maintenance LED
comes on.
The rechargeable battery
was disabled due to a fault.
*
*
Contact your Wacker Neuson contact partner.
Fault
Possible causes
Remedial measure
The machine will not operate.
The charge state of the
rechargeable battery is too low.
Charge the rechargeable battery.
The rechargeable battery is not
properly installed in the machine.
Install the rechargeable battery
properly in the machine.
The rechargeable battery is
defective.
*
The starter lever is in the forward
position when ON switch on the
rechargeable battery was actuated.
Put the starter lever in the OFF
position.
The machine is displaying
unexpected faults during
commissioning or operation.
Refer to the rechargeable battery
faults table.
Press the ON/OFF start button and
remove the rechargeable battery if
the fault persists *