4.4
To Start
See Graphic: wc_gr005324
4.4.1
Open throttle to full position (c4). This will automatically turn on the
flow of fuel.
4.4.2
If machine is equipped, pump the purge bulb
(e)
6 to 10 times or until
you see fuel in bulb.
4.4.3
Close choke (b1).
4.4.4
Pull starter rope (a). Repeat until engine starts. Multiple pulls (typically
less than 5 pulls) may be required to start an engine:
•
that has not been run before.
•
that has not been run for a long period of time (a week or more.)
•
that has been run completely out of fuel.
•
in cold weather conditions.
4.4.5
Reduce throttle to idle (c2) or high idle (c3) position.
4.4.6
Gradually open the choke (b2). Allow engine to warm until it will idle
with the choke fully open.
Note: A warm up period of about one minute may be required in cold
weather.