10 Maintenance
100_0201_mt_0004.fm
29
2. Tilt the vibratory rammer so that it forms a right angle to the ground.
3. Check the oil level through the oil sight glass. Oil must fill 1/2 to 3/4 of the oil sight glass.
4. If the oil level is too low, top off the oil. For the oil specification, see the chapter
Technical Data.
5. Tilt the vibratory rammer forward and secure in this position.
6. Screw on the oil sight glass. Clean the thread on the oil sight glass and wrap with Teflon tape.
7. Fill oil through the opening in the oil sight glass in the housing.
Item
Designation
1
Oil sight glass
NOTICE
Do not overfill the ramming system with oil. An oil level that is too high can lead to a
hydraulic lock in the ramming system. This can lead to faulty operation and damage to the
ramming system.