8.12 Instructions for periodic maintenance
To ensure long life, prevent damage and ensure the full functioning of
the safety features the following maintenance must be performed
regularly. Warranty claims can be recognized only if this work is
performed regularly and properly. Failure to perform the prescribed
maintenance work can lead to accidents!
Users of the cut-off saw must not perform any maintenance work not
described in this Instruction Manual. All such work must be carried out
by a WACKER service station.
General
Entire Power Cut
Clean exterior, check for damage. In case of
damage, have repaired by a qualified service
centre immediately
Cutting blade
Clutch
Inspect regularly for damage and wear.
Protection hood
Clean, check position
Before
each start
Cutting blade
Check for damages and make sure the correct
cutting blade for the planned aplication has
been filted.
V-belt
Check V-belt tension.
Combination
switch, Safety
locking button,
Throttle lever
Functional check.
Fuel tank plug
Check for tightness.
Every day
Prefilter
Clean. (Replace after 20 running hours)
Idle speed
Check (cutting blade must not turn on idle).
Every
week
Fan housing
Clean to ensure proper air cooling.
Starter
Check for damage.
V-belt
Check V-belt tension, inspect for damage and
wear.
Air filter cartridge
Clean. (Replace after 100 running hours)
Spark plug
Check and replace if necessary.
Muffler
Check tightness of mounting.
Every 3
months
Suction head
Replace.
Fuel tank
Clean.
Bearing
Clutch drum
Clean and regrease.