4.8
Cleaning Sediment Cup - Honda
See Graphic: wc_gr000029
4.8.1
Turn the fuel valve off.
4.8.2
Remove the sediment cup (a) and the O-ring (b).
4.8.3
Wash both thoroughly in a nonflammable solvent. Dry and reinstall
them.
4.8.4
Turn the fuel valve on and check for leaks.
4.9
Cleaning Fuel Strainer - Wacker
See Graphic: wc_gr001093
4.9.1
To remove water and dirt, close the fuel lever and remove the fuel
strainer.
4.9.2
Inspect the fuel strainer (a) for water and dirt.
4.9.3
After removing any dirt and water, wash the fuel cup with a
nonflammable solvent.
4.9.4
Reinstall securely to prevent leakage.