Maintenance
T00989GB.fm
25
7.3
Hydraulic control
7.3.1
Check oil level:
1. Move centre pole into vertical position.
2. Open filler bore (26).
3. Oil level must be at mark, if necesary top up with hydraulic oil Fuchs
Renolin MR 520.
4. Close filler bore (26).
7.3.2
Venting hydraulic control:
1. Remove apron (28) by undoing the screws (29).
2. Move centre pole into vertical position, move shift lever (6) right into
the reverse position, open filler bore (26).
3. Loosen connecting screw (27).
4. Slowly push the shift lever (6) into forward motion direction until
hydraulic oil emerges bubblefree at the connection screw.
5. Tighten connecting screw (27), mount apron (28).
6. If necessary, top up with Fuchs Renolin MR 520, seal filler bore (26).