5 Setup and function
18
100_0202_sf_0010.fm
5.3.3
Machine configuration system
In the machine configuration system, machine parameters can be changed by the user (e.g. switching
an activation PIN on or off).
5.3.4
Machine protection – installation (optional)
The acceleration load of the upper mass is monitored via a sensor. When a threshold value
corresponding to an operation of the vibratory plate on an extremely hard surface (concrete, asphalt) is
exceeded, a warning is given to the operator that the vibrator plate is overloaded. This warning is that
the control lamp on the center pole head or the receiving unit will flash red.
In addition, the machine will respond in one of the following ways (adjustable in the machine
configuration):
Only an entry in the error memory.
Lowering the excitation speed.
Shutdown of the machine with entry in the error memory.
Switch-over to slow mode.
5.3.5
Compatec system (optional)
The Compatec system is integrated into the rear protective hood and is located within the operator’s line-
of-sight. The display, which consists of eight light-adjusting LEDs, displays the relative compaction
progress while driving by successively lighting up. When the number of illuminated LEDs no longer
increases, this means that no further compaction can be achieved with the machine. The operator can
finish the work and avoid unnecessary passes.
The overload display indicates if the machine is being operated on too hard of a surface. The operator
is notified of this through an alternating flashing of the LED's.
The Compatec system is suitable for all highly compactable and mixed (well graded) soils.
5.4
Versions
This operator's manual covers the following models:
NOTICE
The Compatec system only supports soil compaction and does not replace the
professional measuring of soil density by an expert.
Versions
Description
r
Remote start
m
Machine protection – installation
c
Compatec system