10 Troubleshooting
58
100_0202_ts_0010.fm
22
Charge controller/
start error.
Charge controller, starter motor, or
electrical connection is defective.
Have the machine repaired.*
Battery is discharged or defective.
Charge or replace battery.
23
Diesel valve error
Diesel valve is defective.
Machine cannot be switched off.
Have the machine repaired.*
24
Gas adjuster error
Fuel tank is empty.
Top up fuel.
Gas adjuster or electrical connection
is defective.
Cable pull of the gas adjuster is
incorrectly set or is defective.
80 A fuse has blown.
Have the machine repaired.*
25
Hydraulic
temperature sensor
error
Hydraulic temperature sensor outside of
the valid range.
26
Oil pressure
shutdown
Engine oil level is too low.
1. Deactivate machine.
2. Top up motor oil.
Oil pressure switch or electrical
connection is defective.
Have the machine repaired.*
27
Overload sensor error
Overload sensor or electrical connection
is defective.
28
Overload sensor error
Defective overload sensor.
29
IR receiver error
Incorrect current value.
30
IR receiver error
No power/not connected.
31
Shutdown of the
center pole unit
No signal/not connected.
32
Shutdown error of the
decoder
Internal error.
33
34
35
Shutdown of the
center pole unit
No signal.
-
Decoder error
Electrical connection in the electrical
box is defective.
1. Deactivate machine with
emergency stop switch.
2. Have the machine
repaired.*
Display of different errors that
alternate in direct succession.
Earth connection of the engine / upper
mass or electric box / upper mass is
loose or defective.
Have the machine repaired.*
*
Have this work performed by the service department of your Wacker Neuson contact partner.
Error code
Display
Possible causes
Remedial measure