Hydraulic system
Important information on the hydraulic system
Danger
!
Burn hazard when performing maintenance on a hot engine and
hydraulic system.
Can cause serious injury or death.
☞
Wait at least 10 minutes after stopping the engine.
☞
Wear protective equipment.
Danger
!
Danger of fluid escaping under high pressure! Removing the filler
plug can cause oil to escape.
Can cause serious injury or death.
☞
Do not operate the machine with leaking or damaged hydraulic system
components.
☞
Open the breather filter carefully to slowly release the pressure inside the
reservoir.
☞
Wear protective equipment.
☞
Wear safety glasses to protect the eyes. If oil contacts the eye, flush imme-
diately with clean water and seek medical treatment.
Notice!
In order to avoid damage to the hydraulic system:
• Use hydraulic oil and grade according to fluids and lubricants table.
• Always add hydraulic oil using the filling screen.
• If the hydraulic oil in the sight glass is cloudy, this indicates that water or air has
penetrated the hydraulic system. Contact a Wacker Neuson service center.
• If the hydraulic system is filled with biodegradable oil, then use only biode-
gradable oil of the same type for filling up – observe the sticker on the hydraulic
oil reservoir.
• Contact a Wacker Neuson service center if the filter of the hydraulic system is
dirty.
Summary of Contents for E09-01
Page 8: ...1 6 BA 1404 en Edition 2 7 Ba1404en2_7IVZ fm Table of contents...
Page 23: ...BA 1404 en Edition 2 7 1404b110 fm 1 13 Introduction Overview of safety labels...
Page 171: ...BA 1404 en Edition 2 7 1404b560 fm 5 43 Maintenance DIN 51 502 DIN 51 825 1000156007 1...
Page 172: ...5 44 BA 1404 en Edition 2 7 1404b560 fm Maintenance...