Safety Information
E 1100
wc_si000628gb.fm
16
Before
operating the
genset
Know how to start, operate, and stop the genset before starting it.
Obtain the proper training for operating the genset. Do not allow untrained
personnel to operate or service the genset.
Check the fuel lines and the fuel tank for leaks and cracks before starting the
engine.
Clean the genset of any spilled fuel.
Running the
genset
Do not start the engine if fuel has spilled or a fuel odor is present.
Keep the area around the exhaust pipe free of flammable materials.
Do not smoke while operating the genset.
Keep sparks, flames, electrical arcs, and other sources of ignition far away from
the genset.
Do not touch the engine or muffler while the engine is running or immediately
after it has been turned off.
Do not operate the genset with the maintenance covers off.
Do not overload the genset. The total amperage of the tools and equipment
attached to the genset must not exceed the load rating of the genset.
Do not operate the genset with wet hands.
Do not remove the radiator cap when the genset is running or is hot.
Refueling
safety
When adding fuel to the fuel tank:
Do not smoke.
Do not refuel a hot or running engine.
When adding fuel to the fuel tank:
Keep sparks, flames, electrical arcs, and other sources of ignition far away from
the genset.
Refill the fuel tank only in a well-ventilated area.
Reinstall the fuel tank cap after refueling.
Maintenance
safety
Only a trained technician should attempt to repair the genset.
Test procedures which require that the generator be running must be performed
using extreme caution.
Make sure clothing and shoes are dry, stand on a dry wooden platform or rubber
insulating mat, and use tools with insulated handles when servicing the genset.
Engine antifreeze is toxic to humans and animals. Clean up spills and dispose
of used engine antifreeze in accordance with local environmental regulations.
Make sure all fasteners are secure and torqued properly.
Summary of Contents for E1100
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram...
Page 160: ......
Page 161: ......