BA EZ17 en* 1.1 * ez17w700.fm
7-29
Maintenance 7
Checking the water separator
Water separator
Empty the water separator if the red indicator ring
A
rises to position
B
.
Emptying the water separator
Information
The fuel system can be bled automatically even if the engine is at
operating temperature
– see chapter “ Bleeding the fuel system” on page 7-31.
1. Stop and park the machine. Stop the engine. See “Preparing
lubrication”.
2. Prepare a suitable container for collecting the fuel/water mixture.
3. Open the engine cover.
4. Turn the ball valve
D
to
Off
.
➥
Fuel supply is interrupted.
5. Unscrew threaded ring
E
.
6. Collect the fuel/water mixture in a suitable container.
7. Screw on the thread ring
E
.
➥
The indicator ring is at the base of the water separator.
8. Turn ball valve
D
to
On
.
➥
Fuel supply is open.
9. Close and lock the engine cover.
Fig. 214
A
B
Fig. 215
D
Off
E
On
Summary of Contents for E13-01
Page 6: ...EG 2 BA EZ17 en 1 1 ez17konf fm Declaration of conformity Notes...
Page 36: ...2 22 BA EZ17 en 1 1 Safety_01_0 fm 2 Safety Notes...
Page 45: ...BA EZ17 en 1 1 ez17e300 fm 3 9 Introduction 3 Warning labels...
Page 50: ...3 14 BA EZ17 en 1 1 ez17e300 fm 3 Introduction Labels...
Page 90: ...4 36 BA EZ17 en 1 1 ez17i400 fm 4 Putting into operation Notes...
Page 158: ...5 68 BA EZ17 en 1 1 ez17b510 fm 5 Operation Notes...
Page 216: ...7 50 BA EZ17 en 1 1 ez17w710 fm 7 Maintenance Notes...
Page 220: ...8 4 BA EZ17 en 1 1 ez17b800 fm 8 Malfunctions Notes...
Page 244: ...9 24 BA EZ17 en 1 1 ez17t900 fm 9 Technical data Dimensions Fig 243...
Page 246: ...9 26 BA EZ17 en 1 1 ez17t900 fm 9 Technical data Notes...