BA EZ17 en* 1.1 * ez17b510.fm
5-63
Operation 5
5.13 Options
Immobiliser
A
= starting key (blue)
For starting the machine. Scope of delivery includes 2 keys.
B
= master key (red)
Coding new starting keys
1. Insert master key
B
in the starter and turn it to position
1
for a
maximum five seconds.
2. Remove master key
B
.
3. Keep master key
B
at least 50 cm (20 in) away from the starter.
4. Within 15 seconds, turn starting keys requiring coding to position
1
for
at least one second.
5. Repeat step 4 if more starting keys require coding.
➥
With this the coding of the starting keys is completed.
Coding can be performed for a maximum of 10 starting keys.
Information
The procedure is automatically cancelled if no key requiring coding is
detected by the system within 15 seconds.
Deleting coded keys
Deleting all coded keys is necessary whenever a coded key is lost.
The master key code is not deleted during deletion.
1. Insert master key
B
in the starter and turn it to position
1
for at least 20
seconds.
2. Code the starting keys.
Information
Store the master key in a safe place. It can only be used for coding new
starting keys.
A new immobilizer must be installed if the master key is lost.
Fig. 177
B
A
Fig. 178
0
1
2
3
P
Summary of Contents for E13-01
Page 6: ...EG 2 BA EZ17 en 1 1 ez17konf fm Declaration of conformity Notes...
Page 36: ...2 22 BA EZ17 en 1 1 Safety_01_0 fm 2 Safety Notes...
Page 45: ...BA EZ17 en 1 1 ez17e300 fm 3 9 Introduction 3 Warning labels...
Page 50: ...3 14 BA EZ17 en 1 1 ez17e300 fm 3 Introduction Labels...
Page 90: ...4 36 BA EZ17 en 1 1 ez17i400 fm 4 Putting into operation Notes...
Page 158: ...5 68 BA EZ17 en 1 1 ez17b510 fm 5 Operation Notes...
Page 216: ...7 50 BA EZ17 en 1 1 ez17w710 fm 7 Maintenance Notes...
Page 220: ...8 4 BA EZ17 en 1 1 ez17b800 fm 8 Malfunctions Notes...
Page 244: ...9 24 BA EZ17 en 1 1 ez17t900 fm 9 Technical data Dimensions Fig 243...
Page 246: ...9 26 BA EZ17 en 1 1 ez17t900 fm 9 Technical data Notes...