Extension cable
A permitted extension cable must fulfill the following criteria:
The extension cable must be undamaged.
The extension cable has to be connected correctly on plug and bushing.
The extension cable has to be suitable for use at construction sites: Average
rubber hose H05RN-F or better – Wacker Neuson recommends H07RN-F or
a country-specific equivalent design.
The extension cable must have been checked by a qualified electrician.
The required cross-section area of a designated extension has been taken
from the table below.
Note:
Refer to the nameplate or the chapter
Technical data
(via the item num-
ber) for the type designation and voltage rating of your machine.
Extension cable for the US market:
Machine
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
EH 6 M
EHB 7 M
230
< 86
1.5
< 142
2.5
EH 6 M
EHB 7 M
110-120
< 22
1.5
< 37
2.5
< 59
4.0
Machine
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
EH 6 M
EHB 7 M
230
< 246
16
< 390
14
EH 6 M
EHB 7 M
110-120
< 102
14
< 161
12
< 253
10