T00066GB
8
MAINTENANCE
Maintenance schedule
Check all external screw connections for tight fit approx. 8 hours after first operation.
Component
Maintenance work
Maintenance interval
Feed line
Check for perfect condition - if cable
daily
defective, replace.
Miscellaneous
Fan slits dirt - free - clean if necessary.
Tools
Check the shafts and cutting edges - if necessary,
sharpen, reforge or replace.
Miscellaneous
Regrease via grease nipples.
20 hours
Tool bush
Check for wear - change if necessary.
monthly
Carbon brush
Check for wear, remaining length about 9 mm
80 hours
- change if necessary.
Miscellaneous
Check cheese head screws of housing for tight
fit retighten if necessary - 25 Nm.
Miscellaneous
Regrease crankshaft drive.
600 hours
Maintenance and lubrication
1. General instructions
Keep hammer and tools clean.
2. Motor
Carbon brushes: This hammer is equipped with automatic switch-off carbon brushes. Thes brushes switch-
off the hammer as soon as their length is worn down to approx. 9 mm. Therefore, before starting a long
operation check brushes for wear. Replace if necessary.
3. Mechanical part
Every 20 hours of operation moderately grease crank mechanism and percussion system via lubricating
nipple situated on crankcase (see technicla data). Use special grease. Check tool holder brushing for wear.
The tool may have a play of max. 6 mm at a distance of approx. 200 mm from the entrance. If the bushing
is worn to a greater degree, replace it to avoid damages and operational failures.