![background image](http://html1.mh-extra.com/html/wacker-neuson/ez17/ez17_operators-manual_3134811170.webp)
7-24
OM EZ17 us 1.0 * ez17w700.fm
7
7.6
Lubrication work
Preparing lubrication
1. Stop the machine on firm, level and horizontal ground.
2. Position the boom straight ahead at the center of the machine.
3. Lower the boom and the stabilizer blade to the ground.
4. Stop the engine.
5. Operate the control lever repeatedly to release the pressure in the
hydraulic system.
6. Raise the control lever base.
7. Remove the starting key and carry it with you.
8. Remove loose objects from inside the machine.
9. Close and lock the engine cover and the other covers.
10.Attach a warning label to the control elements (for example “Machine
being serviced, do not start”).
11.Wait at least 10 minutes after stopping the engine!