![background image](http://html1.mh-extra.com/html/wacker-neuson/ez17/ez17_operators-manual_3134811177.webp)
OM EZ17 us 1.0 * ez17w700.fm
7-31
7
Emptying the fuel filter
Information
The fuel system can be bled automatically even if the engine is at
operating temperature
– see chapter “ Bleeding the fuel system” on page 7-29.
1. Stop and park the machine. Stop the engine. See “Preparing
lubrication”.
2. Open the engine cover.
3. Connect a drain hose to port
B
. Place the hose into a container on the
ground.
4. Prepare a suitable container for collecting the fuel/water mixture.
5. Open screw
C
.
6. Collect the fuel/water mixture in a suitable container.
7. Close screw
C
.
8. Remove the hose.
9. Close and lock the engine cover.
Information
Use a suitable container to collect engine/machine fluids as they flow out
and dispose of them in an environmentally friendly manner.
Fig. 196
C
B