Maintenance
50Hz Mobile Generators
wc_tx000885gb.fm
42
4.9
Lubricating the Trailer
Prerequisites
Engine off
Trailer chocked
Multi-purpose grease to DIN 51825 KTA 3K4
When
Every 10,000–15,000 km of service or yearly
Procedure
Follow the procedure below to lubricate the trailer.
1. Grease the drawbar
(1)
in the area of the bellows.
2. Grease the bearing bushing through the grease nipple
(2)
on the housing and
the cartridge.
3. Grease the pivot bolt
(3)
of the overrun lever and the handbrake levers through
the grease nipple.
4. Grease the end of the brake rod end fitting
(4)
.
5. Oil the joints of the spring cylinder in the handbrake lever
(5)
.
wc_gr005250