Basic Troubleshooting
50Hz Mobile Generators
wc_tx000896gb.fm
56
6
Basic Troubleshooting
Problem
Cause
Remedy
Engine doesn’t start
Battery discharged
Battery connections cor-
roded
Defective starter
Charge battery.
Clean battery connections.
Replace starter.
Engine tries to start but
stops
No fuel
Clogged fuel filter
Fuel circuit failure
Speed regulator failure
Fill tank with fuel.
Replace fuel filter.
Check fuel lines.
Call for service.
Engine doesn’t reach oper-
ating speed
Fuel circuit failure
Speed regulator failure
Voltage regulator malfunc-
tion
Check fuel lines.
Call for service.
Call for service.
No generator output
Voltage regulator malfunc-
tion
Overload switch ON
Triggered switch. Short cir-
cuit or earth fault.
Call for service.
Reduce load.
Check circuits downstream
by checking faults in equip-
ment and/or connection
cables.
Low oil pressure
Low oil level
Clogged oil filter
Oil pump failure
Alarm failure
Fill engine sump with oil.
Replace oil filter.
Call for service.
Check connections
between sensor and panel.
If necessary, replace sen-
sor.
High coolant temperature
Overload
Low coolant level
Clogged oil filter
Oil pump failure
Reduce load.
Fill with coolant.
Replace oil filter.
Call for service.
Engine overspeed
Speed regulator failure
Overload switch ON
Alarm failure
Call for service.
Reduce load.
Check connections
between sensor and panel.
If necessary, replace sen-
sor.
Black smoke
Fuel circuit failure
Clogged air filter
Overload
High oil level
Call for service.
Clean/replace air filter car-
tridges.
Reduce load.
Remove excess oil.
Summary of Contents for G 43
Page 1: ...Mobile Generator G 43 OPERATOR S MANUAL 0175257en 001 0608 0 1 7 5 2 5 7 E N...
Page 2: ......
Page 4: ...Foreword G 43 wc_tx000898gb fm 4...
Page 13: ...50Hz Mobile Generators Safety Information wc_si000271gb fm 13 Notes...
Page 18: ...Transporting Lifting and Storing 50Hz Mobile Generators wc_tx000895gb fm 18 Notes...
Page 48: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 48 5 Schematics 5 1 Power Wiring...
Page 50: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 50 5 3 Engine Wiring...
Page 52: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 52 5 5 Socket Wiring...
Page 54: ...Schematics 50Hz Mobile Generators wc_tx000886gb fm 54 5 7 Control Wiring...
Page 57: ...50Hz Mobile Generators Basic Troubleshooting wc_tx000896gb fm 57...
Page 60: ...Technical Data G 43 wc_td000277gb fm 60 7 3 Dimensions...
Page 62: ......
Page 64: ......