G 2.5A
Portable Generator Repair
wc_tx000207gb.fm
32
5.4
Capacitor
See Graphic: wc_gr000934
A capacitor (c) is connected in series with the auxiliary winding. Its
purpose is to regulate the voltage when a load is applied.
5.5
Diodes
See Graphic: wc_gr000934
Two diodes (d) are located on the rotor. These diodes form a half-wave
rectifier to convert the induced AC voltage in the rotor windings to DC
voltage.
w c _ g r 0 0 0 9 3 4