Adjusting Engine Speed
See Graphic: wc_gr000032
Generators require a fixed engine speed to maintain the correct
voltage. Engine speed is controlled by a governor which automatically
adjusts to varying loads on the engine to maintain a constant speed.
There is no throttle control.
To set the engine to the proper speed:
Turn the speed adjusting screw
(b)
in or out to obtain a no-load speed.
See
Technical Data
.
CAUTION:
Setting the engine speed too high or too low may damage
tools and other appliances attached to the generator.
6.9
Storage
Before storing the generator for a long period of time:
6.9.1
Close the fuel valve and remove and empty the sediment cup or fuel
strainer.
6.9.2
Disconnect the fuel line from the carburetor. Place open end of fuel line
into a suitable container and open fuel valve to drain fuel from tank.
Gasoline is extremely flammable. Drain the fuel tank in a well-
ventilated area. DO NOT drain the fuel tank in an area with flames or
sparks.
6.9.3
Loosen the drain screw on the carburetor and drain any remaining fuel
from the carburetor.
6.9.4
Change the engine oil.
6.9.5
Remove the spark plug and pour approximately 30 ml (1 ounce) of
clean engine oil into the cylinder. Crank the engine a few turns to
distribute the oil to the inside of the cylinder walls.
6.9.6
Pull the starter rope slowly until resistance is felt and leave the handle
in this position. This ensures that the intake and exhaust valves are
closed.
6.9.7
Store the generator in a clean, dry area.
WARNING
Summary of Contents for GP 2500A
Page 1: ...www wackergroup com Generator GP 2500A OPERATOR S MANUAL 0160531en 002 1106 0 1 6 0 5 3 1 E N...
Page 13: ...GP 2500A Safety Information wc_si000149gb fm 11 3 5 Label Locations GND 88897...
Page 37: ...GP 2500A Maintenance wc_tx000448gb fm 35...
Page 38: ...Maintenance GP 2500A wc_tx000448gb fm 36 Notes...
Page 39: ......