Maintenance
HDR 115
Continued from the previous page.
The following internal components of the machine require regular cleaning to
maintain optimum performance.
Enclosure (all areas must be free of dirt and debris)
Ventilator
(b)
High-tension connectors
(c)
CAD (Cadmium) cell
(d)
Turbulator
(e)
Electrodes
(f)
Burner nozzle
(g)
Air tube
(h)
Procedure
Perform the procedure below to clean the interior components of the machine.
1. Remove the access panel. See topic
Removing the Access Panel.
2. Use compressed air to clean the enclosure and ventilator
(b)
.
3. Inspect and clean the high-tension connectors and wires
(c)
. Replace any
damaged or worn components.
4. Remove the burner assembly. See topic
Removing and Installing the Burner
Assembly
.
5. Check/clean the CAD cell
(d)
. See topic
Inspecting and Cleaning the CAD Cell
.
6. Check electrodes
(f)
. See topic
Checking and Adjusting the Electrodes
.
7. Check the burner nozzle
(g)
. See topic
Replacing the Burner Nozzle.
Result
The machine has been inspected and cleaned.