ghi_tx001462gb_FM10.fm
31
HI400HD D / HD G
Operation
4.4
Blower Duct Heater Option
Overview
An optional 10 cm (4 in.) duct for preheating air drawn into the combustion blower
can be installed. This accessory is recommended for use in extremely cold
temperatures.
Note:
The installation instructions below are provided for your convenience. Refer
to the complete instruction sheet packaged with the blower duct kit.
Prerequisites
■
Blower duct kit (includes 10 cm (4 in.) snorkel and flexible duct with integral
clamps)
■
Phillips screwdriver or nut driver
■
Flat screwdriver
Procedure
Perform the procedure below to install the blower duct.
1. Remove the square plate from the bottom of the front duct adapter. Replace the
square plate with the 10 cm (4 in.) snorkel
(a)
and tighten the screws securely.
2. Install the front duct adapter according to the instructions provided in
Installing
the Front Duct Adapter
.
3. Fit one end of the blower duct
(b)
over the 10 cm (4 in.) snorkel and tighten the
clamp. In the same manner, connect the other end to the 10 cm (4 in.) supply
outlet
(c)
on the side of the machine.
NOTICE:
Do not connect a blower duct longer than 4.5 m (15 ft.) to the snorkel.
wc_gr008219
a
b
c
Summary of Contents for HI400HD D
Page 4: ...CALIFORNIA Proposition 65 Warning Proposition 65 Warning 4 wc_tx004643en fm Notes ...
Page 8: ...Foreword HI400HD D HD G 8 ghi_tx001460gb_FM10 fm ...
Page 12: ...12 wc_bo5000192824_11TOC fm HI400HD D HD G Table of Contents ...
Page 27: ...ghi_si000469gb_FM10 fm 27 HI400HD D HD G Labels Fork lift pocket ...
Page 85: ...wc_td000604gb_FM10 fm 85 HI400HD D HD G Technical Data Notes ...
Page 92: ......
Page 94: ......