4.25
Starting the Machine (G models)
Requirements
■
Machine properly positioned
■
Power connected
■
Pre-starting checks completed
Procedure
Perform the procedure below to start the machine.
1. Select an operation mode
(b)
.
a. Continuous heat mode (I)
b. thermostat mode (II)
Operational
sequence
The following sequence of events will occur.
1. The blue light on the gas regulator will illuminate, indicating that gas is flowing.
2. The burner blower will start.
3. The burner will start firing.
■
In applications in which the remote thermostat is not being used (I), the
burner will fire continuously.
■
In applications in which the remote thermostat is being used (II), the burner
will fire until the air temperature of the application area reaches the target
temperature set by the remote thermostat. At that time, the burner will shut
off, but the blower will continue to operate. When the air temperature of the
application area falls below the target temperature set by the remote
thermostat, the burner will refire. The process continues as long as there is
fuel for the burner.
4. The main blower will begin blowing warm air when the combustion chamber is
hot.
RESET
Summary of Contents for HI400HD D
Page 4: ...CALIFORNIA Proposition 65 Warning Proposition 65 Warning 4 wc_tx004643en fm Notes ...
Page 8: ...Foreword HI400HD D HD G 8 ghi_tx001460gb_FM10 fm ...
Page 12: ...12 wc_bo5000192824_11TOC fm HI400HD D HD G Table of Contents ...
Page 27: ...ghi_si000469gb_FM10 fm 27 HI400HD D HD G Labels Fork lift pocket ...
Page 85: ...wc_td000604gb_FM10 fm 85 HI400HD D HD G Technical Data Notes ...
Page 92: ......
Page 94: ......