wc_td000604gb_FM10.fm
84
Technical Data
HI400HD D / HD G
9
Technical Data
9.1
Machine
Model
HI400HD D
HI400HD G
Units
Gross burner heat input
BTU/hr (kW)
412,682 (120.8)
NG: 380,548 (111.4)
LP: 334,700 (98)
Net heat output
BTU/hr (kW)
341,288 (99.9)
NG: 329,174 (96.4)
LP: 289,515 (84.8)
Air flow
cfm
3015
3015
Fuel consumption
L/hr (gph)
11.2 (2.97)
—
Fuel consumption
—Natural gas (NG)
—Liquid propane (LP)
m
3
/hr (cfh)
L/hr (gph)
—
10.1 (355.97)
13.8 (3.65)
Fuel nozzle size
L/hr (gph)
7.6 (2.0) (80W)
—
Fuel nozzle size
mm (in.)
—
3 x 2.8 (12 x 0.11)
Efficiency
%
82.7
82.8
Noise level at 1 m
dB (A)
76
74
Power requirement
VAC/Hz
120/60
120/60
Electrical current (@15°C)
Ampere
13
11.8
Weight (no fuel)
kg (lb)
206.8 (456)
225.4 (497)
Height
mm (in.)
1308 (51.5)
1105 (43.5)
Length
mm (in.)
2134 (84)
2134 (84)
Width
mm (in.)
838 (33)
838 (33)
Flue diameter
mm (in.)
152.4 (6)
152.4 (6)
Fuel tank capacity
L (gal)
216.1 (57.1)
—
Fuel pressure
psi (bar)
Stage I: 1
81
(1
2.5
)
Stage II: 217 (15)
—
Fuel supply pressure
—Natural gas
—Liquid propane (LP)
WC (Pa)
—
Min 7, Max 10
Min 8, Max 13
Burner pressure
—Natural gas
—Liquid propane (LP)
WC (Pa)
—
6.40 (1600)
6.52 (1630)
Air damper setting
number
1.5
3
Static air pressure limit
WC (Pa)
0.60 (150)
Summary of Contents for HI400HD D
Page 4: ...CALIFORNIA Proposition 65 Warning Proposition 65 Warning 4 wc_tx004643en fm Notes ...
Page 8: ...Foreword HI400HD D HD G 8 ghi_tx001460gb_FM10 fm ...
Page 12: ...12 wc_bo5000192824_11TOC fm HI400HD D HD G Table of Contents ...
Page 27: ...ghi_si000469gb_FM10 fm 27 HI400HD D HD G Labels Fork lift pocket ...
Page 85: ...wc_td000604gb_FM10 fm 85 HI400HD D HD G Technical Data Notes ...
Page 92: ......
Page 94: ......