Air conditioning (optional) (currently not available)
Information on putting the air conditioning into operation
When cooling, as well as when heating, the air conditioning system
supplies dehumidified and purified air to the cabin.
In order to achieve best air conditioning results:
• Before putting into operation, ventilate the cabin thoroughly.
• Close the windows and doors.
• Set the fan to maximum output first, and then adjust it to your needs.
• In order to prevent condensation water from forming on the condenser,
switch off the air conditioning system in due time
before the end of work.
NOTICE
Observe the following points in order to avoid malfunctions, loss of
refrigerant and drying-out of the seals:
►
Run the air conditioning system at least once a month.
►
Clean the heat exchanger (condenser) regularly. Daily in dusty or dirty
work conditions
– see chapter 7 “Air conditioning (opt) (currently not available)” on
page 7-81
►
Have the air conditioning checked at least once a year by an
authorized service center.
►
Repair, maintenance and filling with refrigerant must be performed by
trained personnel and an authorized service center.
Information
The air conditioning system runs on electricity and is supplied with power
by the battery. The higher the performance of the air conditioning system,
the higher the energy consumption. This means that with increasing
system output, the operating time of the battery diminishes accordingly.
The performance of the air conditioning system is therefore limited.
When outside temperatures are very high, we recommend:
– parking the machine when it is not being used out of the sun and
– to observe the instructions for how to operate the air conditioning.
Summary of Contents for KRAMER 5055e
Page 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Page 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Page 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Page 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Page 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Page 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Page 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Page 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Page 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Page 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Page 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...