5-36
BA 357-00 * 3.0 * 35700_05_Bedienung.fm
5 Operation
Oil volume setting
Using the oil volume setting during continuous operation of the 3rd control
circuit (
– see "Continuous operation of 3rd control circuit" on page 5-44
) to
set the rpm of the operating motor and thus indirectly the flow rate of the
hydraulic pump. The flow rate, in turn, has an impact on the hydraulic
function of the attachments.
Information
If an additional speed is required because other hydraulic functions are
being used at the same time (e.g. raising/lowering the loader unit) that is
above the speed set with the oil volume setting, the speed will be raised to
the needed value for as long as the requirement persists.
The oil volume setting requires the following conditions to be fulfilled:
• Machine is turned on and ready to operate
– see chapter 4 “Turn on the machine” on page 4-54
• Operator is sitting in position.
• Joystick lock for road travel is unlocked
– see chapter 4 “Locking/unlocking the control lever (joystick)” on
page 4-51
The rotary switch for the oil volume adjustment
is located on the rear
switch panel to the right of the operator seat.
Information
The oil volume can be set variably between 0 % (700 min
-1
)
and 100 % (3000 min
-1
). Ex works, the oil volume is set to 100%.
Information
The selected oil volume is set permanently until it is changed manually.
Information
The oil volume settings can only be increased / reduced during machine
operation, e.g. the number of revolutions a rotary broom makes.
Fig. 129
Summary of Contents for KRAMER 5055e
Page 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Page 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Page 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Page 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Page 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Page 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Page 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Page 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Page 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Page 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Page 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...