BA 357-00 * 3.0 * 35700_07_Wartung.fm
7-83
Maintenance 7
Cleaning the heat exchanger (condenser)
CAUTION
Risk of injury due to hot parts!
Touching hot components can result in injury.
►
Allow the machine to cool down.
►
Wear protective equipment.
1. Apply the parking brake.
2. Turn the machine off and remove the ignition key.
3. Remove cover
A
from the protective screen.
4. Clean heat exchanger
C
with a water jet
(do not use a high-pressure cleaner or compressed air).
5. Clean the air-intake area at the protective screen.
6. Install the cover
A
.
Information
Dehumidifier
B
has to be replaced
every 2 years by an authorized service center.
Fig. 257
A
B
C