BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8-15
Malfunctions 8
Operator presence switch
Error code FMI
Warning
light
Error description
Remedy
519053
4
Yellow
S104: Signal range exceeded or short circuit to
machine ground/sensor ground
– Machine travel function is blocked
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
26
Yellow
S104: Signal outside of the valid range
– Machine travel function is blocked
28
Yellow
S104: Open circuit or short circuit to
positive supply voltage
– Machine travel function is blocked
Summary of Contents for KRAMER 5055e