8-34
BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Immobilizer (continuation)
Error code FMI
Warning
light
Error description
Remedy
518082
26
–
N021 –
Relays 1 Status: short circuit
(voltage if relays contacts are open)
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
27
–
N021 –
Relays 1 Status: open circuit
(no voltage if relays contacts are closed)
518083
26
–
N021 –
Relays 2 Status: short circuit
(voltage if relays contacts are open)
27
–
N021 –
Relays 2 Status: open circuit
(no voltage if relays contacts are closed)
518084
26
–
N021 –
Relays 3 Status: short circuit
(voltage if relays contacts are open)
27
–
N021 –
Relays 3 Status: open circuit
(no voltage if relays contacts are closed)
518085
10
–
N021 –
CAN-Bus-Status: receiver error
518086
16
–
N021 –
Battery status: Overvoltage (29.8 V)
18
–
N021 –
Battery status: Undervoltage (7.7 V)
518087
13
–
N021 –
Immobilizer active
Check if the right key was
used.
518089
02
–
N021 –
Reservoir full
Reduce number of keys.
Summary of Contents for KRAMER 5055e
Page 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Page 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Page 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Page 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Page 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Page 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Page 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Page 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Page 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Page 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Page 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...