8 Malfunctions
8.4
Malfunctions in the air conditioning system (opt)
Only authorized service centers and trained personnel may perform
repairs, and fill up and empty the air conditioning system!
Malfunctions in
the air conditioning system
Possible causes
Remedy
See
page
Fan does not run
Malfunctioning or loose fuse
Replace fuses
Interrupted line
Contact an authorized service
center
–
Malfunctioning fan motor
–
Malfunctioning fan switch
–
Fan cannot be switched off
Short circuit in cable or fan
switch
–
Reduced fan output
Dirty contacts
–
Undersized electric lines
–
Condenser very dirty
Cleaning the condenser
Insufficient heating output or
none at all
Condenser fins dirty
Cleaning the condenser
Dirty filter
Clean the filter
Loss of refrigerant on equipment
Loose hose connection
Contact an authorized service
center
–
Damaged hose
–
Condenser damaged
–
Compressor does not run
Malfunctioning controls
–
Loose connection on compressor
–
Condenser overflow
Expansion valve is stuck in open
position
Contact an authorized service
center
–
Clogged condenser
Dirty radiator fins
Clean the condenser
Summary of Contents for KRAMER 5055e
Page 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Page 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Page 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Page 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Page 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Page 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Page 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Page 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Page 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Page 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Page 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...