Operation
7.8 Starting, Operating, Stopping the Machine—Kohler
64
Operator’s Manual | LTV 4L/6L | 5100065071 | 02/2023 | [en-US]
the engine stops. You must return the starting key to the OFF position
for 30 seconds before restarting the engine.
Operating the lights
wc_gr013753
1
2
3
4
5
Fig. 36: Starting, operating, and stopping controls
1.
Turn on the main circuit breaker
(1)
.
2.
Turn on individual circuit breakers
(3)
one at a time.
Notes
• Metal halide floodlights require a warm-up time of 5–15 minutes before
they reach full brightness.
• After turning the lights off, a cool-down time of 10 minutes is necessary
before they can be turned on again.
Stopping the machine
NOTICE
Failure to turn off lights may cause damage to the electrical system.
►
Turn off the lights before stopping the engine.
1.
Remove all connected loads from the machine.
2.
Turn the circuit breakers
(1, 2, and 3)
off.
3.
Rotate the starting key
(5)
to the OFF position.