Operation
7.14 Emergency Shutdown Procedure
74
Operator’s Manual | LTV 4L/6L | 5100065071 | 02/2023 | [en-US]
4.
Save and exit the editor by pressing and holding the Auto button. To
exit without saving, press and hold Stop.
5.
Enter the editor mode. Press and hold the Stop
(3)
and Auto
(4)
but-
tons simultaneously.
6.
Press the up or down arrows to select the Operator Editor (human
icon). Refer to the following table.
7.
Save and exit the editor by pressing and holding the Auto button. To
exit without saving, press and hold Stop.
8.
Press the Auto button once. The indicator LED above the Auto button
illuminates.
9.
Place the main breaker and both lamp breakers in the UP position
(closed).
The machine is now in Auto Start mode.
Shortly before the sun sets, the machine will start and turn on the lamps au-
tomatically.
When the sun rises, the machine will turn off the lamps and then shut down.
This cycle will continue until the machine is taken off Auto mode by pressing
the red Stop button.
Configuration Editor Parameters for Auto Start by Photo Cell
333
Enable Photo Cell
(0) OFF,
(20) ON
(20 enables photo cell)
Operator Editor Parameters for Auto Start by Scheduler or by Location
901
Enable Scheduler
(0) OFF
, (1) ON (0 disables scheduler)
7.14
Emergency Shutdown Procedure
WARNING
Personal injury hazard
Raising or lowering the tower creates situations that if not avoided, will
cause death or serious injury from striking, crushing, pinching, electrocution,
etc.
►
Keep the area under and around the lights clear of people and obstruc-
tions while raising and lowering the tower.
General procedures
Perform the procedure below if a breakdown or accident occurs while the
machine is operating:
1.
Stop the engine.
2.
Disconnect all loads from the machine.
3.
Lower the tower.
4.
Allow the machine to cool before opening the cabinet.
Summary of Contents for LTV 4L
Page 4: ...This page is intentionally left blank...
Page 104: ...Index 104 Operator s Manual LTV 4L 6L 5100065071 02 2023 en US...
Page 105: ......