wc_tx004431gb_FM10.fm
72
Operation
LTV
6. Start the engine on the machine that is being used as a power source.
7. Wait for a minimum of two minutes while the battery in the stalled machine
partially charges.
8. Turn the engine key switch and hold it until the engine starts.
NOTICE:
Cranking the engine for more than five seconds can cause starter damage. If the
engine fails to start, release the key switch and wait 10 seconds before operating
the starter again. If the engine still fails to start see Troubleshooting.
9. Immediately after the stalled engine starts, disconnect the negative cable clamp
first from the previously dead battery and then the negative cable clamp of the
booster battery.
10.Disconnect the positive cable clamp from the booster battery and then the
positive cable clamp from the previously dead battery.
11.When using light or high amperage draw accessories, idle the engine for a
period of 20 minutes to bring the battery to charge state.
Result
The machine has now been jump-started.
Summary of Contents for LTV6L