10 Use and operation
34
100_0101_op_0008.fm
10.2
Starting up
Connecting the HMS to the power supply
NOTICE
Electrical voltage.
Incorrect voltage can cause damage on the machine.
X
Check if the voltage of the current source corresponds with the information
of the machine, see chapter Technical Data.
WARNING
Electrical voltage.
Injuries from electrocution.
X
Check power cable and extension cable for signs of damage.
X
Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data
).
WARNING
Starting of the machine.
Danger of injuries from uncontrolled starting of the machine.
X
Deactivate the machine before connection to the electric power supply.
WARNING
Danger of electric shock and short-circuit!
Serious injuries from electric shock.
X
Check power cable and extension cable for signs of damage.
X
Extension cable is not protected by GFCI.
X
Machines with damaged GFCI may not be operated.
X
The GFCI may only be replaced by a qualified electrician from Wacker
Neuson service.
X
Never use the tool without the GFCI provided with the tool.
X
Always test the correct operation of the GFCI before starting work, unless
the GFCI is of a selfchecking type.
X
Protect the GFCI from moisture. Do not submerge into water.
X
Avoid exposure of GFCI to chemicals.
X
Use only with extension cord described in chapter Technical Data.