wc_tx001644gb_FM10.fm
18
Installation
PS2 800 / PSA2 800
3.8
Connecting the Power Supply
Before connecting leads to the terminal strip, make certain the power supply is
turned off (circuit breaker, etc.), to avoid electrical shock, shorting, or unexpected
starting of the pump, leading to injury.
Before inserting the power supply plug, make certain the power supply is turned off
(circuit breaker, etc.), to avoid electrical shock, shorting, or unexpected starting of
the pump, leading to injury.
Do not use the pump with the cable assembly or plug connected loosely, which can
result in electric shock, shorting, or fire.
Draw power from a dedicated power outlet rated at 15A or above. Sharing the
outlet with other equipment may cause overheating at the branch outlet and could
result in fire.
NOTICE
:
Be sure to use a dedicated power supply with a ground leakage circuit
breaker.
Grounded
plug
Connect only to receptacle of proper voltage and current rating matching that of the
plug provided with the cable assembly.
Without plug
Tighten the ends of the cable assembly securely against the terminal board. If
installation of a grounded plug is required, use only a properly rated and approved
CEE plug and secure the ends of the cable assembly securely to power and
ground terminals in accordance with the plug manufacturer’s instructions.
WARNING
CAUTION
Br
L
L1 L2
G/Y
wc_gr000309