Maintenance
PT 3 / PT 3A / PT 3H
40
wc_tx001776gb.fm
5.8
Spark Plug (Wacker Neuson / Honda)
See Graphic: wc_gr000028
Clean or replace the spark plug as needed to ensure proper operation.
Refer to your engine operator’s manual.
The muffler becomes very hot during operation and remains hot for a
while after stopping the engine. Do not touch the muffler while it is hot.
Note:
Refer to section “Technical Data” for the recommended spark
plug type and the electrode gap setting
.
5.8.1
Remove the spark plug and inspect it.
5.8.2
Replace the spark plug if the insulator is cracked or chipped.
5.8.3
Clean the spark plug electrodes with a wire brush.
5.8.4
Set the electrode gap
(a)
.
5.8.5
Tighten the spark plug securely.
NOTICE
:
A loose spark plug can become very hot and may cause
engine damage
.
WARNING