Operation
Exhaust gas after-treatment
104
BA RC50_RC70 en 00
The switch [3] flashes if parked regeneration has been cancelled. Parked
regeneration must be initiated again as soon as possible.
3.22.02
Urgency of regeneration
Stage 1:
Regeneration required
a
The switch [3] flashes.
The diesel particulate filter cannot be regenerated at low operating
temperatures.
Raise the machine's operating temperature by increasing the engine
load (e.g. by increasing the engine speed to the maximum, switching
on the vibration)
If independent regeneration is not possible, parked regeneration must be
carried out in a safe location as soon as possible.
Stage 2:
Carry out parked regeneration immediately
a
The switch [3] flashes.
a
The indicator light [2] flashes yellow.
a
The speed and output of the diesel engine are reduced.
The machine is locked for normal operation to prevent damage to the
diesel engine and the exhaust gas system.
Drive the machine out of the danger area.
Carry out parked regeneration.
Stage 3:
Regeneration by service personnel required
a
The switch [3] flashes.
a
The indicator light [2] lights up yellow.
a
The warning light [4] lights up.
a
The speed and output of the diesel engine are reduced.
The machine is locked for normal operation to prevent damage to the
diesel engine and the exhaust gas system.
Move the machine out of the danger area and park it in a safe
location.
Contact customer service.
Stage 4:
Replace the diesel particulate filter
a
The indicator light [2] lights up red.
If the level of ash in the diesel particulate filter has reached its maximum
value, the filter must be replaced. This work may only be carried out by
trained personnel.
Move the machine out of the danger area and park it in a safe
location.
Contact customer service.
Summary of Contents for RC50
Page 10: ...EC Declaration of Conformity 10 BA RC50_RC70 en 00 EC DECLARATION OF CONFORMITY...
Page 24: ...Preface Type plate 24 BA RC50_RC70 en 00...
Page 161: ...Tables Technical data BA RC50_RC70 en 00 161...
Page 180: ...Tables Dimension sheet 180 BA RC50_RC70 en 00 5 02 Dimension sheet 5 02 01 RC50 5 02 02 RC50p...
Page 181: ...Tables Dimension sheet BA RC50_RC70 en 00 181 5 02 03 RC70 RC70vo 5 02 04 RC70p...
Page 220: ......
Page 221: ......