Maintenance
Hydraulic oil supply
BA RC50_RC70 en 00
145
4.04.02
Changing the hydraulic oil and ventilation filter
$
Only lubricants with this symbol are permitted (
onwards).
2
1
3
Switch off diesel engine and remove ignition key.
Allow machine to cool down less than 30 ° (86 °F).
Unscrew oil drain screw [3] down on the oil tank and discharge the
used oil drain into a provided receptacle.
Remove ventilation filter [2] and replace by a new one.
Screw in oil drain screw [3] and tighten.
Fill up specified oil through filling spout [2].
Correct oil level: Centre of sight glass [1].
Tighten ventilation filter [2].
Start the diesel engine.
Actuate drive lever with low engine speed until the transmission
activates.
Also actuate the steering.
a
The pipes and hose lines will be filled with oil and vented.
Check oil level with the diesel engine at a standstill. Top up oil if
necessary.
Check hydraulic system for leaks.
4.04.03