RCE
Technical data
Operator’s manual
49
Extension cable for the US market:
Example
You utilize a RCE-20/230 and want to use an extension cable with a length of
50 m (164 ft).
The machine has an input voltage of 230 V.
According to the table, the extension cable must feature a cross-section area of
1.5 mm
2
(AWG 14).
Machine
Voltage
[V]
Extension
[ft]
Cross-section
area of cable
[AWG]
RCE-16
115
< 95
16
< 148
14
< 233
12
< 371
10
120
< 98
16
< 154
14
< 243
12
< 384
10
230
< 295
16
< 469
14
RCE-20/25
115
< 85
16
< 138
14
< 217
12
< 341
10
120
< 89
16
< 141
14
< 282
12
< 354
10
230
< 325
16
< 492
14