Maintenance
RCP
8.2.2
Changing the knife
Performing preparations
1. Pull the plug from the plug receptacle.
2. Open the protective hood (only installed on some machine designs).
Changing the fixed knife
1. Unscrew both fastening screws on the fixed knife.
2. Changing fixed knife.
3. Tighten fixed knife with both fastening screws.
Changing the movable knife
1. Unscrew both fastening screws on the movable knife and remove with the
spring washers.
2. Changing movable knife.
3. Tighten movable knife with both fastening screws and spring washers.
Item
Designation
1
Fixed knife
2
Fastening screw (2 pieces)
3
Movable knife
4
Fastening screw with spring
washer (2 pieces)