SE RvICINg A ND INSPEC TION
213
W L 30
10.9 Loader storage
The specified measures refer to shutting down and re-start
-
ing the loader over longer periods of time.
Follow the Operator’s Manual for the engine.
Shutting down the loader
1. Park the loader as described in section 9, page 129
»Securing the loader«.
2. Engage the articulated frame lock (Ref. Section 6.2,
page 118).
3. Raise the loader so that the tires no longer touch the
ground.
4. Release the parking brake.
5. Lower the loader lift arms and attachment to the ground.
6. Relieve residual hydraulic pressure, ref. Section 8, page
126 »Relieving residual pressure in the hydraulic sys-
tem«. Move all hydraulic controls to the neutral position.
7. Spray bare metal parts of the loader (e.g.: the piston
rods of the hydraulic cylinders if they are not retracted)
with an anti-corrosion agent.
8. Preserve the engine.
Note:
Before beginning the shutdown procedures, drive the
Wheel Loader to its storage location.