6.4 Durability
Item
Test condition
Specification
6.4.1
Operating life
time of
puressure
switch
(1) Operating speed
: 5 times/sec
(2) Applied pressure
: 2.94 [N]
(3) Operating cycle
: 2,000,000 times
No malfunction
6.4.2
Operating life
time of side
switch
(1) Operating speed
: 3 times/sec
(2) Applied pressure
: 1.8 [N]
(3) Operating cycle
: 100,000 times
No malfunction
6.4.3
Drop test
(1) Height: 80[cm]
(2) Cycle: 15
(3) Floor surface: Iron plate
(4) Fall method: To drop a sylus in horizontal attitude
No malfunction
6.4.4
Break test
Apply load at the point as shown below.
No breakage
6.4.5
Charge
function
Pen to operate appropriately after recharging-
discharging for 50 times (charging period is 300[sec] as
full-charge status).
No malfunction