Instruction Booklet - D4000 and D5000 Series Omnidirectional

3

ASSEMBLY

 

 
 

    

1.  Loosen the clamping screws on the antenna.  See mounting detail. 

     2.  Pull downleads up through the mounting pipe and make the                                                                                                                                                                  
 

connection to the antenna. 

     3.  If grounding your equipment, do so at this time by following                                                                                                                                                                                                   
 

the Safety Precautions procedure. 

     4.  Slide the clamping end of the antenna onto the mounting pipe.   
     5.  Alternately secure the clamping screws making sure to keep the                                                                                                                                                                                              
 

mounting pipe centred with the antenna.   

     6.  After final tightening, lock clamping screws into position using the 
 

supplied stainless steel hex nuts. 

    

 

 

ANTENNA 

(5000 Series shown) 

CLAMPING SCREW 

MOUNTING PIPE

 (MAST) 

ANTENNA ASSEMBLY 

 
   

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 
 
 

 
 

 
 
 
 
 

MOUNTING DETAIL 

(4000 Series shown) 

CLAMPING 
SCREW 

MOUNTING PIPE 

(MAST) 

GROUND WIRE 

S.S. LOCK NUT 

ANTENNA 

DOWNLEADS 

CENTER (VHF) 

GROUND LUG 

(4000 SERIES ONLY) 

LOWER (UHF) 

UPPER (UHF) 

ANTENNA ASSEMBLY

Loosen the clamping screws on the antenna. See mounting detail.

1. 

Pull downleads up through the mounting pipe and make the 

2. 

connection to the antenna.
If grounding your equipment, do so at this time by following the Safety 

3. 

Precautions procedure.
Slide the clamping end of the antenna onto the mounting pipe.

4. 

Alternately secure the clamping screws making sure to keep the 

5. 

mounting pipe centred with the antenna.
After final tightening, lock clamping screws into position using the 

6. 

supplied stainless steel hex nuts.

Assembly

Summary of Contents for D4061A1

Page 1: ...TACOAntenna A d i v i s i o n o f WA D E A n t e n n a I n c D4000 D5000 SERIES OMNI DIRECTIONAL VHF UHF Antennas INSTRUCTION BOOKLET ...

Page 2: ...olTM concept The utilization of this technique results in a unit having excellent broadband halfwave dipole characteristics over its entire specified frequency bandwidth The desired figure eight radiation pattern is generally constant throughout the band Through broadband suppression of extraneous currents upon the transmission line the undesirable Clover Leaf pattern is avoided A grounding lug is...

Page 3: ...5 44 1 D4077 1 225 400 2 0 75 N1 30 5 77 5 5 0 2 27 2 D4078 3 225 400 2 0 75 N3 121 5 308 6 17 0 7 71 1 D5062A 1 225 400 4 5 40 N1 69 5 176 5 13 5 6 12 2 D5074 2 225 400 2 0 75 N2 85 0 215 9 12 0 5 44 1 D5077 1 225 400 2 0 75 N1 30 5 77 5 5 0 2 27 2 D5078 3 225 400 2 0 75 N3 121 5 308 6 17 0 7 71 1 VHF AND UHF FREQUENCIES MODEL OF OUTPUTS FREQUENCY RANGE MHz GAIN dBic Max HPBW DEGREE TERMINAL TYPE...

Page 4: ...ning lock clamping screws into position using the supplied stainless steel hex nuts ANTENNA 5000 Series shown CLAMPING SCREW MOUNTING PIPE MAST ANTENNAASSEMBLY 4 ANTENNA ASSEMBLY Loosen the clamping screws on the antenna See mounting detail 1 Pull downleads up through the mounting pipe and make the 2 connection to the antenna If grounding your equipment do so at this time by following the Safety 3...

Page 5: ...000 Series Omnidirectional 4 MOUNTING DETAIL 4000 Series shown CLAMPING SCREW MOUNTING PIPE MAST GROUND WIRE S S LOCK NUT ANTENNA DOWNLEADS CENTER VHF GROUND LUG 4000 SERIES ONLY LOWER UHF UPPER UHF 5 MOUNTING DETAIL 4000 SERIES SHOWN ...

Page 6: ...t 2 into the ground Keep antenna and cable a safe distance from any power lines 3 Safety Precautions SAFETY PRECAUTIONS To protect your antenna and receiver from lightning damage you should ground your equipement 1 Slide the ground wire 6 recommended into the ground lug as shown below and tighten the 10 32 x 3 8 set screw 2 Connect the ground wire to a ground rod driven at least four 4 feet into t...

Page 7: ...D 810F Temperature barometric pressure and humidity to MIL STD 210C Temperature 50 C to 70 C Relative Humidity 5 to 100 Altitude Sea Level To 10 000 ft 3 048 m Filament Wound Fiberglass Radome ENVIRONMENTAL Rugged Lightweight Construction Transportable Compact Combination of UHF and VHF options High isolation between antenna elements Features Lightning Rod L Bird Cap BC Aluminum Base A Frequency A...

Page 8: ...om of the lens close the ring on the bottom groove of the lens and reinstall the screw 3 Place the lens on the lamp as shown below and clamp down using the lamp clamps 8 OBSTRUCTION LAMP DETAIL Install supplied light bulb 100 Watt 130 Volts industrial in lamp 1 socket Remove one screw on the clamping ring and open it to slide onto the 2 bottom of the lens close the ring on the bottom groove of the...

Page 9: ...om horizon Applied Power 100 Watts Max Mechanical Specifications Height 111 in 281 9 cm Weight 14 lbs 6 4kg Mount Mast Diameter 3 in 7 62 cm Wind Load Area No Ice 1 5 sq ft Wind Load Area 1 2 in Ice 2 0 sq ft Environmental Specifications Rain salt fog sand dust and fungus to MIL STD 810A and B Temperature Barometric Pressure and Humidity to MIL STD 210 and 210A Radome Material Filament Wound Fiber...