59
VAS 581 001A
Service tasks
“Service completed”
displays the amount of service work performed
using the air conditioning service unit since the last reset (see date).
9.8
Filling level correction for longer service hoses
I
1. In the basic menu, use the cursor keys
or
to select
“Other
selections”
:
2. Press
ENTER
to confirm.
3. Use the cursor keys
or to select
“Service”
:
4. Press
ENTER
to confirm.
5. Enter the password
“7732”
.
6. Enter the hose length in centimeters.
7. Press
ENTER
to confirm.
Service performed:
03/07/17
Qty
4
STOP-EXIT
NOTE
If longer or shorter service hoses are required for the device, you
need to adjust the filling quantities to the new hose lengths.
The service hoses for the high and low pressure sides must always
be of the same length, as otherwise the filling quantities will not be
correctly measured.
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.