EN
Service tasks
AirConServiceCenter
104
9.2
Changing the dryer filter
1. In the basic menu, use the cursor keys
or
to select
“Free
selection”
:
2. Press
ENTER
to confirm.
3. Skip the query requesting
“CAR DATA”
.
4. Select
“Rec/Recycling phase”
.
5. Set the
“Pressure increase test time”
to
“1”
.
Press
ENTER
to confirm.
6. Deselect
“Vacuum phase”
using
“No”
.
Press
ENTER
to confirm.
7. Deselect
“Filling phase?”
using
“No”
.
Press
ENTER
to confirm.
8. Select
“Process start?”
.
Press
ENTER
to confirm.
The service hoses will now be drained and the AirConServiceCenter
basic menu will be activated. The compressor has produced a slight
internal vacuum so that the filter can be replaced with minimal refrig-
erant loss.
9. Unscrew the screw (
D
) from the holder, and pull the dryer filter
straight out.
Short selection
Free selection
Other selections
ENTER-OK
D