EN
Technical data
AirConServiceCenter
118
12
Technical data
The display shows
“Error 52”
No USB stick was found/rec-
ognised
Insert the USB stick.
Make sure that the USB stick
has been formatted with the
FAT32 file system.
The display shows
“Error 60”
During the hybrid service
(flushing the service hoses
with hybrid oil), a vacuum
could not be achieved.
Are the service hoses con-
nected to the hybrid flush
container?
Is the hybrid flush container
fitted the right way round?
Check the connections for
leaks.
The display shows
“Error 61”
Pressure increase during the
hybrid service .
Are the service hoses con-
nected to the hybrid flush
container?
Is the hybrid flush container
fitted the right way round?
Are the service couplings
open?
AirConServiceCenter
ASC1000G
Dimensions (width x height x depth):
560 mm x 1300 mm x 650 mm
Weight:
95 kg
Power supply:
230 V/240 V – 50 Hz/60 Hz
Refrigerant extraction rate:
18 kg/h
Vacuum pump output:
4 cars/h
Hermetic compressor output:
0.2 kW
Drier filter output:
150 kg
Filling cylinder accumulator capacity:
12.0 l/10.0 kg
Noise emission:
55.5 dB (A)
Accuracy of the electronic scale for refrigerant:
± 10 g
Accuracy of the electronic scale for old/new oil/
UV additive:
± 1 g
Operating temperature:
+ 5 °C – + 45 °C
Problem
Cause
Remedy